Treatment Levels of Ozone For Microbial Species
[fusion_global id=”6752″][fusion_builder_container type=”flex” hundred_percent=”no” hundred_percent_height=”no” hundred_percent_height_scroll=”no” align_content=”stretch” flex_align_items=”flex-start” flex_justify_content=”flex-start” hundred_percent_height_center_content=”yes” equal_height_columns=”no” container_tag=”div” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” status=”published” padding_top=”0″ padding_right=”0″ padding_bottom=”0″ padding_left=”0″ border_style=”solid” box_shadow=”no” box_shadow_blur=”0″ box_shadow_spread=”0″ gradient_start_position=”0″ gradient_end_position=”100″ gradient_type=”linear” radial_direction=”center center” linear_angle=”180″ background_position=”center center” background_repeat=”no-repeat” fade=”no” background_parallax=”none” enable_mobile=”no” parallax_speed=”0.3″ background_blend_mode=”none” video_aspect_ratio=”16:9″ video_loop=”yes” video_mute=”yes” absolute=”off” absolute_devices=”small,medium,large” sticky=”off” sticky_devices=”small-visibility,medium-visibility,large-visibility” sticky_transition_offset=”0″ scroll_offset=”0″ animation_direction=”left” animation_speed=”0.3″ filter_hue=”0″ filter_saturation=”100″ filter_brightness=”100″ filter_contrast=”100″ filter_invert=”0″ filter_sepia=”0″ filter_opacity=”100″ filter_blur=”0″ filter_hue_hover=”0″ filter_saturation_hover=”100″ filter_brightness_hover=”100″ filter_contrast_hover=”100″ filter_invert_hover=”0″ filter_sepia_hover=”0″ filter_opacity_hover=”100″ filter_blur_hover=”0″][fusion_builder_row][fusion_builder_column type=”1_1″ type=”1_1″ layout=”2_3″ align_self=”auto” content_layout=”column” align_content=”flex-start” valign_content=”flex-start” content_wrap=”wrap” center_content=”no” column_tag=”div” target=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” sticky_display=”normal,sticky” order_medium=”0″ order_small=”0″ hover_type=”none” border_style=”solid” box_shadow=”no” box_shadow_blur=”0″ box_shadow_spread=”0″ background_type=”single” gradient_start_position=”0″ gradient_end_position=”100″ gradient_type=”linear” radial_direction=”center center” linear_angle=”180″ lazy_load=”none” background_position=”left top” background_repeat=”no-repeat” background_blend_mode=”none” filter_type=”regular” filter_hue=”0″ filter_saturation=”100″ filter_brightness=”100″ filter_contrast=”100″ filter_invert=”0″ filter_sepia=”0″ filter_opacity=”100″ filter_blur=”0″ filter_hue_hover=”0″ filter_saturation_hover=”100″ filter_brightness_hover=”100″ filter_contrast_hover=”100″ filter_invert_hover=”0″ filter_sepia_hover=”0″ filter_opacity_hover=”100″ filter_blur_hover=”0″ animation_direction=”left” animation_speed=”0.3″ last=”true” border_position=”all” first=”true” min_height=”” link=””][fusion_title title_type=”text” rotation_effect=”bounceIn” display_time=”1200″ highlight_effect=”circle” loop_animation=”off” highlight_width=”9″ highlight_top_margin=”0″ title_link=”off” link_target=”_self” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” sticky_display=”normal,sticky” content_align=”left” size=”1″ fusion_font_family_title_font=”Inter” fusion_font_variant_title_font=”700″ font_size=”36″ text_color=”#333333″ text_shadow=”no” text_shadow_blur=”0″ gradient_font=”no” gradient_start_position=”0″ gradient_end_position=”100″ gradient_type=”linear” radial_direction=”center center” linear_angle=”180″ style_type=”none” animation_direction=”left” animation_speed=”0.3″]
Recommended Treatment Levels of Ozone For Particular Microbial Species
[/fusion_title][fusion_text hide_on_mobile=”small-visibility,medium-visibility,large-visibility” sticky_display=”normal,sticky” fusion_font_family_text_font=”Inter” fusion_font_variant_text_font=”400″ font_size=”18″ line_height=”1.5″ text_color=”#222222″ animation_direction=”left” animation_speed=”0.3″]
There is a two-step procedure for determining the recommended treatment levels of ozone. First, the grams of ozone that you need to produce to oxidize the grams of contaminants. The second is the disinfection calculation, measured in mg/l of ozone over a specific period. Inactivating a living organism requires concentration and time (Ct).
[/fusion_text][fusion_table fusion_table_type=”1″ fusion_table_rows=”17″ fusion_table_columns=”4″ hide_on_mobile=”small-visibility,medium-visibility,large-visibility” animation_direction=”left” animation_speed=”0.3″]
Organism |
Concentration (ppm) |
Minutes |
CT |
|---|---|---|---|
| Algae (blue-green) | 0.3 | 5.0 | 1.5 |
| Bacteria (all species), recommended | 0.1 | 1.0 | 0.1 |
| Escherichia coli (E. coli) | 0.04 | 1.0 | 0.04 |
| coliphage MS2 | 0.2 | 0.5 | 0.1 |
| Heterotrophic Bacteria HPC | 0.2 | 0.5 | 0.1 |
| Mycobacterium tuberculosis, leprae | 0.01 | 6.0 | 0.06 |
| Pseudomonas aeruginosa, fluorescens | 0.01 | 0.1 | 0.01 |
| Salmonella, all | 0.01 | 0.1 | 0.01 |
| Staphylococcus, sp, albus, aureus | 0.01 | 0.1 | 0.01 |
| Streptococcus, all | 0.01 | 2.0 | 0.02 |
| Fungus, Mold, Yeasts | 0.3 | 5.0 | 1.5 |
| Nematodes, all, recommended | 1.0 | 5.0 | 5.0 |
| Protozoa, all, recommended | 1.5 | 5.0 | 7.5 |
| Acanthamoeba & Naegleria | 0.2 | 0.5 | 0.1 |
| Amoeboe Trophozoites cysts | 0.4 | 4.0 | 1.6 |
| Cryptosporidium, recommended | 1.5 | 5.0 | 7.5 |
Information written for the Drinking Water Unit of EPA’s Region 10 by Jim Eagleton.
[/fusion_table][fusion_text hide_on_mobile=”small-visibility,medium-visibility,large-visibility” sticky_display=”normal,sticky” fusion_font_family_text_font=”Inter” fusion_font_variant_text_font=”400″ font_size=”18″ line_height=”1.5″ text_color=”#222222″ animation_direction=”left” animation_speed=”0.3″]Note
- The CT factor is the product of the ozone concentration (ppm) and the contact time (minutes). Essentially, the higher the CT factor, the more difficult the organism is to kill.
- Amicrobial species with a CT factor of 0.01 for example will be killed by an ozone concentration of 0.01 mg/L for a contact time of 1 minute or an ozone concentration of 1.0 mg/L for 0.01 minutes, (0.6 seconds).
Contact us now if you require more information on the subject or technical assistance with sizing an Ozone system[/fusion_text][/fusion_builder_column][/fusion_builder_row][/fusion_builder_container]